1.Wrap the cuff around your client's arm above the elbow not too tight or too
loose
2. Tum the screw to close it inflate the cuff until the dial points to 30 mm above the
palpated systobe pressure
3 Tum the screw to close 1 Inflate the cuff until the dal points to 30 mm above the
palpated systolic pressure
* Find your chent's brachial pulse at the inside of the elbow Hok the diaphragm
there and inflate the cuff until the puise disappears
5 Expose the arm of your client by rolling the sleeves up Have your chent's arm
from the elbow down to rest fully extended on the bed or the arm of a chair
6 Ask your client to rest quietly Have himher lie down or sit on a chair whichever
is more comfortable for him/her
7 Sanitize the earpieces of the stethoscope with an antiseptic pad
8 Deflate the cuit compiole, Remove it from the arm of your client and record the
reading on the client's chart.
9 Introduce yourself and let the patient/client know the procedure to be done
10. If you are using a mercurial apparatus, the measuring scale should be within the
level of your eyes
11 Unroll the cuff, loosen the screw and squeeze the cuff with your hands to
remove air completely.
12 Place the stethoscope's earpieces into your ears and place the diaphragm on the
brachial pulse
13 Turn the screw to open it. Let the air escape slowly until the sound of the pulse
comes back.
14 You have lo continue releasing the air from the cuff. When you hear the sounds
change to something softer and faster and disappear, take note of the
calibration
15 Wipe the earpieces of the stethoscope with an antisepbe pad and place the
equipment back to their proper place and wash your hands.